Description
Make: Sunsynk 10kW
Inverter
Battery Input Data
Battery Type: Lead-acid or Lithium-ion
Battery Voltage Range: 40~60V
Max. Charging Current: 220A
Max. Discharging Current: 220A
Charging Curve: 3 Stages/Equalisation
External Temperature: Yes
Charging Li-Ion Battery: Self-Adaptation to BMS
PV String Input Data
Max. DC Input Power: 13000W
Rated PV Input Voltage: 370V (125~500V)
Start-up Voltage: 125V
MPPT Voltage Range: 150V-425V
Full Load DC Voltage Range: 200V-425V
PV Input Current: 26A+26A+26A
Max. PV Isc:44A+44A+44A
No. of MPPT / Strings Per MPPT: 3 / 2+2+2
AC Output Data
Rated AC Output Active Power: 10000
Max AC Output Active Power: 11000
AC Output Rated Current: 45.5/43.5A
Max. AC Output Current: 50/47.9A
Max. Continuous AC Passthrough: 70A
Peak Power (Off Grid): 2 Time of Rated Power, 10 S
Power Factor Adjustment Range: 0.8 Leading to 0.8 Lagging
Power Factor: 1
Spec Sheet: Sunsynk_10kw
Battery
Battery Storage
Battery Chemistry: LiFePO4
Capacity: 100 (Ah)
Scalability: Max. 32 pcs in parallel (163.8kWh)
Nominal Voltage: 51.2 V
Operating Voltage: 44.8~57.6 V
Energy: 5.12 kWh
Usable Energy: [1] 4.61 kWh
Spec Sheet: Sunsynk_G5.1_Datasheet_v2_English_27082025
Solar Input
Solar Panels
Rated Maximum Power: 620w
Open Circuit Voltage: 48.50
Maximum power Voltage: 40.21
Short circuit: 16.13
Maximum Power Current: 15.42
Module efficiency: 23.0
Power Tolerance: 0~+3%
Number of Units: 12
Data Sheet: Datasheet_-_Ja_Solar_JAM72D40_575-600_LB_(EN)_(2)[1]
Balance of System
1 x Keto 250Amp Battery Disconnect Fuse Breaker
1 x 100m x 6mm SGN Solar Cable Red
1 x 100m x 6mm SGN Solar Cable Black
1 x 100mm x 6mm Earth Cable
1 x Set Renusol Roof Mounts (Angle mounts or genuis flashing slate covers not included)
1 x Solar Input Protection Protection Box 2 string in and 2 out
1 x AC Protection Box – Surge Arrestor/2 x 50Amp Breakers/63Amp Changeover
2 x Pairs MC4 connectors
Full Installation Notes
- Installation offering for JHB, Port Elizabeth, Alexandria, Cape Town, Pretoria and within 50kms of those main centers.
- No extreme angle roof types (>30 degrees) and no slate roof types that may require slate kits.
- Extra will have to be charged if panel lifts are required or ladder rental for very high roofs.
- Offer assumes that installation point is within 10M from mains db board.
- Mains DB must have an existing Certificate of Compliance, extra will have to be charged if a COC needs to be done.
- Offer valid while stocks last.