Description
Model: Deye 15kW 3 Phase High Voltage Hybrid Inverter
Battery Input Data
Battery Type: lead acid or Lithium-ion
Battery Voltage Range (V): 40-60
Max. Charging Current (A): 280
Max. Discharging Current (A): 280
Charging Strategy for Li-ion Battery: Self – adaption to Bms
Battery Type: lead acid or Lithium-ion
Battery Voltage Range (V): 40-60
Max. Charging Current (A): 280
Max. Discharging Current (A): 280
Charging Strategy for Li-ion Battery: Self – adaption to Bms
Number of Battery Input: 1
Pv String Input Data
Max. PV Access Power (W): 30000
Max. PV Access Power (W): 30000
Max. PV Input Power (W): 24000
Max. PV Input Voltage (V): 800
Start-up Voltage (V): 160
MPPT Voltage Range (V): 160-650
Rated PV Input Voltage (V): 550
Max. Operating PV Input Current (A): 36+36
Max. Input Short-Circuit Current (A): 54+54
No. of MPP Trackers/: 2/2+2
No. of Strings MPP Tracker: 2/2+2
Start-up Voltage (V): 160
MPPT Voltage Range (V): 160-650
Rated PV Input Voltage (V): 550
Max. Operating PV Input Current (A): 36+36
Max. Input Short-Circuit Current (A): 54+54
No. of MPP Trackers/: 2/2+2
No. of Strings MPP Tracker: 2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W): 15000
Max. AC Input/Output Apparent Power (VA):16500
Rated AC Input/Output Current (A): 22.8/21.8
Max. AC Input/Output Current (A): 25/24
Max. Continuous AC Passthrough (grid to load) (A): 70
Peak Power (off-grid) (W): 2 times of rate power
Power Factor Adjustment Range: 0.8 leading to 0.8 lagging
Rated Input/Output Grid Frequency/Range(Hz): 50/45-55, 60/55-65
Grid Connection Form: 3L+PE
Total Current Harmonic Distortion THDi: <3% (of nominal power)
DC Injection Current: <0.5% In
Efficiency
Max. Efficiency: 97.6%
Euro Efficiency: 97.0%
MPPT Efficiency: >99%
Max. Efficiency: 97.6%
Euro Efficiency: 97.0%
MPPT Efficiency: >99%
Spec Sheet: Deye 15kw ..
Key features:
- 100% unbalanced output, each phase; Max.
output up to 50% rated power - AC couple to retrofit existing solar system
- Max. 10 pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel - Max. charging/discharging current of 350A
- 48V low voltage battery, transformer isolation design
- 6 time periods for battery charging/discharging
- Support storing energy from diesel generator